Liquid Level Sensor
Specifications
Electrodes
Model
CLA-D30P150
CLA-D30P250
CLA-D30P350
Applicable pipe diameter
Φ30mm *¹
Φ30mm *¹
Φ30mm *¹
Liquid-level range
0 to 150mm
0 to 250mm
0 to 550mm
Standard cable length
2m (External diameter Φ4mm Shielded twisted pair cable)
Operating humidity
35 to 75% RH
Insulation resistance
50 MΩ min. between lead wire and case (insulation resistance tester of 500V DC)
Voltage resistance
For one minute at 500 VAC, 50/60Hz between lead wires and electrode surface.
Protective construction
IP-63
Installation
Wind and band together and fix with the provided insulation lock tie.
Secure with double-sided adhesive tape on a flat surface.
*¹ : Securing is possible from Φ24 to a flat surface. Please consult us for details.
Amplifier
Model
CLA-A01
Power supply
DC 12V/DC 24V ±10%
Consumption current
60mA or less
Liquid-surface detection range
Electrode type
Liquid-level detection range
Liquid relative permittivity
Liquid-surface detection range
CLA-D30P150
0 to 150mm
1.8 or more
Liquid-surface detection range
CLA-D30P150
0 to 250mm
1.8 or more
Liquid-surface detection range
CLA-D30P550
Under development
1.8 or more
Analog output
Voltage output: 1V to 5V at upper and lower limit of the liquid surface
Output resistance: 1 KΩ or less
Control output
Upper limit
control output
ON beyond the upper limit setting level
(variable)
Control output
Lower limit
control output
ON below the lower limit setting level
(variable)
Control output
Difference: 10% or less than the set level
Control output
Output circuit structure: NPN transistor open collector
Control output response time
Less than one second
Indicator lamp
Power indication
Green lamp lights up in power-on stateBlinks once when teaching has beencompleted.
Indicator lamp
Upper limit control indication
Red lamp lights while the upper limit control output is being operated.
Indicator lamp
Lower limit control indication
Yellow lamp lights while the lower limit control output is being operated.
Temperature condition influences
Less than ±15% of 3V analog output in 0 to 40°C *²
Voltage influences
Less than ±5% of 3V analog output at the applied voltage 24 VDC ±10% *²
Insulation resistance
50MΩmin. between terminal and case (insulation resistance tester of 500V DC)
Voltage resistance
For one minute at 500 VAC, 50/60Hz between lead wires and electrode surface.
Installation
35mm DIN mounting rail.
*² : This is a reference value for standard electrodes. It varies according to the type of liquid to be detected, and dimensions of the gage pipe. Contact us for details.
Liquid Level Sensor CLA Series
Basic Type
Separated amplifier-type sensor allows detection of the liquid level without coming in contact with the liquid.
Contact Us
Get in touch