Liquid Level Switch
Multi-Point Output Type
- Slim type
Attached with sapce-saving is possible due to the slim 2.0 mm thickness of the sensor part. - Flexible
Mountable even on curved surfaces (Φ30 to flat surface) - Without touching
The electrode is mounted from the outside of the pipe/tank and the detection is made without touching the liquid, so there is no risk of contaminating the liquid or corroding the electrode. - 4CH Multi-head
A single amplifier can be used to connect four electrodes. Since each head is separate, it can be used regardless of the position of the electrodes. - Compatible with non-transparent vessels
Capable of detecting even if the pipe/tank is non-transparent. (Only non-metallic containers can be detected.)
Specifications
Electrode
Model
CLS-D30P20
CLS-D30P20-1
Applicable vessels
Φ30mm to flat surface
Applicable amplifier
CLS-A01 / CLS-A01-1
Standard cable length
2m
5m
Standard cable length
(Outer diameter Φ1.65mm shielded cord)
Ambient temperature range
0~+70℃
Fluctuation of detection ON point is within ±3 mm (detecting the object) at 23°C
Ambient humidity range
25 to 75% RH
Insulation resistance
50MΩ or more between lead wires and electrode surface (at 500V DC megger)
Dielectric strength
500 V AC (50/60 Hz) for 1 minute between current-carrying parts and no current-carrying parts
Leakage current 3mA or less
Degree of protection
IP-67
Outer coating
SBR (styrene-butadiene rubber)
Mounting method
Wrap and tie with an inslock tie
For flat surfaces, use double-sided tape, etc.
Amplifier
Model
CLS-A01
CLS-A01-1
Power supply voltage
DC 12 to 24V
Current consumption
75mA or less
Detection liquid
Liquid with relative permittivity of 20 or higher
(Outer diameter: 30 mm, thickness: 3 mm, material: acrylic pipe mounted)
Control output
Stress difference 0.3 mm to 3 mm (ON, OFF point difference) *¹
Load current Max. 50 mA ( Short-circuit protection circuit built-in )
Residual voltage 1V or less
Response time 300ms or less
Indicator lamp
Power indicator
– Lit (green) when power is turned on
– Blink during teaching when the object to be detected is not on the electrode detection surface.
– Turn off temporarily and turn on again during teaching when the object to be detected is above the upper limit of the electrode detection surface
Output indication
– NO output: Lit (red) when detected
– NC output: Unlit (red) when detected
Output state
NO (NO/NC switching not possible)
NO (NO/NC switching possible) *²
Operating temperature range
0 to +55°C (no condensation or icing )
Operating humidity range
25 to 75%RH
Insulation resistance
50MΩ or more between lead wires and electrode surface (at 500V DC ohmmeter)
Voltage resistance
500V AC (50/60Hz) for 1 minute between current-carrying parts and no current-carrying parts
Leakage current 1mA max.
Degree of protection
IP-30
Mounting method
35mm DIN rail mounting
*¹ : Varies depending on the type of liquid to be detected and the material and dimensions of the gauge tube. Please consult us for details.
*² : All of 1CH to 4CH are set to NO output by default.
Liquid Level Switch CLS Series
Multi-Point Output Type
Detect liquid level at 4 points with slim electrodes.